Laser calculator
Pick your laser, enter your LightBurn settings, read off the physics.
Laser & material
LightBurn settings
The operating parameters you dial into your job.
Power60 %
Source parameters
Adjust to match your exact hardware. Defaults from the selected laser.
Derived metrics
limiting at maxpulsed
Spot Ø
12 µm
measured
Spot area
1.13e-6 cm²
Avg power
3 W
Areal dose
10 J/cm²
energy per unit area
Pulse energy
0.05 mJ
power-limited
Peak power
10,000 W
Pulse fluence
44.21 J/cm²
Peak irradiance
8.84e+9 W/cm²
Pulse pitch
16.7 µm
beam travel between pulses
Overlap along scan
gap
5 µm between pulses
Line overlap
gap
Pulses / point
0.7
along-scan coverage
Energy deposition heatmap
Accumulated dose over a 0.24 mm square of surface. Each dot is one pulse.
gaps between pulses
100 µm
0local dose (J/cm²)88
Select a target material to model peak surface temperature and the marking regime.
Sensitivity sweep
How areal dose responds as one setting varies — everything else held at your current values.
Dashed line marks your current speed = 1,000 mm/s.